Joint AUA/SUNA White Paper on Reprocessing of Flexible Cystoscopes
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری‌های کلیوی
پیش نمایش صفحه اول مقاله
Joint AUA/SUNA White Paper on Reprocessing of Flexible Cystoscopes
چکیده انگلیسی

PurposeNumerous federal bodies and professional societies have produced guidelines and standards for the reprocessing of endoscopes, but few specifically address the reprocessing of cystoscopes.Materials and MethodsThis document presents a summary of the current recommendations for reprocessing flexible cystoscopes, and highlights particular aspects of instrument reprocessing that are unique to cystoscopy.ResultsCystoscopes are classified as “semi-critical” devices. Such devices require high-level disinfection or sterilization between patients. High-level disinfection differs from sterilization in that high-level disinfection does not kill large numbers of bacterial spores, while sterilization involves the complete destruction of all microbial life. In the office setting, high-level disinfection (using glutaraldehyde or another chemical disinfectant) is commonly employed for the reprocessing of flexible cystoscopes. During high-level disinfection, standard reprocessing steps should be followed to prevent contamination of the cystoscope between uses. These include precleaning, leak testing, cleaning, disinfection, rinsing, and drying. Recommended “soak times” for glutaraldehyde vary from 20 to 45 minutes, depending upon the degree to which these steps are followed. If no precleaning is performed, a 45-minute glutaraldehyde soak is required to achieve high-level disinfection. Conversely, a 20-minute soak is adequate to achieve high-level disinfection if recommended reprocessing steps are followed prior to immersion in the glutaraldehyde. One chemical disinfectant (ortho-phthalaldehyde) has been associated with anaphylaxis in bladder cancer patients, and should be avoided in these patients.ConclusionsThis white paper provides a concise reference document for the reprocessing of flexible cystoscopes. In addition, references and links to more comprehensive resources are provided. This document may be useful for clinicians and others who are in search of guidance in this area.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Urology - Volume 184, Issue 6, December 2010, Pages 2241–2245
نویسندگان
, , , , , , , ,