کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3925446 1253128 2013 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Is an Initial Saturation Prostate Biopsy Scheme Better than an Extended Scheme for Detection of Prostate Cancer? A Systematic Review and Meta-analysis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی زنان، زایمان و بهداشت زنان
پیش نمایش صفحه اول مقاله
Is an Initial Saturation Prostate Biopsy Scheme Better than an Extended Scheme for Detection of Prostate Cancer? A Systematic Review and Meta-analysis
چکیده انگلیسی

ContextThe optimal initial prostate biopsy core number is still an issue with many unanswered questions and significant controversy.ObjectiveTo compare diagnostic values of initial saturation prostate biopsy scheme and extended scheme with respect to prostate-specific antigen (PSA) levels, prostate volume (PV), and PSA density (PSAD).Evidence acquisitionElectronic databases including Medline, Web of Knowledge, and the Cochrane Library were searched through November 1, 2012. Experts were consulted, and references from relevant articles were scanned. The meta-analysis was conducted with RevMan 5.1, according to the PRISMA guidelines. Mantel-Haenszel estimates were calculated and pooled under a fixed or random effect model, with data expressed as risk difference (RD) and 95% confidence interval (CI).Evidence synthesisWe analyzed eight trials with a total of 11 997 participants who underwent transrectal ultrasound guided prostate biopsies for the first time and met inclusion criteria. Studies consisted of one paired design study, two randomized clinical trials, and five nonrandomized studies. Saturation biopsy scheme showed a significant advantage in prostate cancer (PCa) detection over an extended scheme (RD: 0.04; 95% CI, 0.01–0.08; p = 0.02). In addition, subgroup analyses found a saturation protocol to be superior to an extended protocol in the detection of PCa in men with PSA <10 ng/ml (RD: 0.04; 95% CI, 0.01–0.07; p = 0.002), PV >40 ml (RD: 0.05; 95%CI, 0.01–0.09; p = 0.02), or PSAD <0.25 ng/ml per gram (RD: 0.04; 95% CI, 0.00–0.09; p = 0.04).ConclusionsThe existing evidence indicates that an initial saturation biopsy scheme is more efficient than an extended scheme for PCa detection, especially for those men with lower PSA levels, higher PV, or lower PSAD, without increasing complications and the amount of insignificant cancer.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Urology - Volume 63, Issue 6, June 2013, Pages 1031–1039
نویسندگان
, , , , , , , ,