کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
398876 | 1438746 | 2014 | 11 صفحه PDF | دانلود رایگان |
In this paper, linear proportional–integral (PI) and nonlinear flatness-based controllers for dc link stabilization for fuel cell/supercapacitor hybrid power plants are compared. For high power applications, 4-phase parallel boost converters are implemented with a switching interleaving technique for a fuel cell (FC) converter, and 4-phase parallel bidirectional converters are implemented with a switching interleaving technique for a supercapacitor converter in the laboratory. As controls, mathematical models (reduced-order models) of the FC converter and the supercapacitor converter are given. The prototype small-scale power plant studied is composed of a PEMFC system (the Nexa Ballard FC power generator: 1.2 kW, 46 A) and a supercapacitor module (100 F, 32 V, based on Maxwell Technologies Company). Simulation (by Matlab/Simulink) and experimental results demonstrate that the nonlinear differential flatness-based control provides improved dc bus stabilization relative to a classical linear PI control method.
• The comparison of linear and nonlinear controls for FC/SC power plant is studied.
• A 1.2-kW FC system and a 100-F SC module were used in the implements.
• Simulation and experimental results demonstrate the comparison of two controllers.
• The nonlinear control shows better performance than the linear control.
Journal: International Journal of Electrical Power & Energy Systems - Volume 54, January 2014, Pages 454–464