کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4042086 1603482 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Quadrupled Hamstring Graft Strength as a Function of Clinical Sizing
ترجمه فارسی عنوان
چهاردهمین بار استحکام کشش همسترینگ به عنوان عملکرد اندازه بالینی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

PurposeThis study sought to compare the strength of quadrupled hamstring tendon (QHT) grafts of 6 to 9.5 mm in clinical diameter with that of 10-mm bone–patellar tendon–bone (BPTB) grafts.MethodsTwenty cadaveric semitendinosus and gracilis tendons were combined into QHT grafts. These were sized using a standard graft-sizing device and an area micrometer, yielding grafts ranging from 6 to 9.5 mm in diameter. The grafts were tested to failure. Five 10-mm BPTB grafts were also sized and tested.ResultsClinical sizing did predict the strength of the graft but not profoundly. As a material alone, without consideration of fixation in bone tunnels, QHT grafts were stronger than BPTB grafts. Graft strength decreased with size, but a linear relation between strength and diameter (r2 = 0.715, P < .001) was found to be as good as the expected quadratic fit (r2 = 0.709). Compared with BPTB grafts, even the smallest QHT grafts (diameter <6.5 mm) were still significantly stronger than 10-mm BPTB grafts (P = .004). The elastic moduli of the QHT and BPTB grafts were 761 ± 187 MPa and 615 ± 403 MPa, respectively; elongations at failure were 12.0% ± 2.0% and 7.5% ± 1.6%, respectively; and failure stresses were 105 ± 18 MPa and 50 ± 14 MPa, respectively.ConclusionsThis work shows that a clinical size of QHT grafts of 6 mm in diameter is not a concern regarding the strength itself. For a possible lower-end prediction of acceptable size, assuming that a gracilis-semitendinosus graft would have only the stress of the weakest measured QHT graft of 88 MPa, a graft of 5.5 mm in diameter would suffice, having more strength in newtons than the average patellar tendon.Clinical RelevanceClinically sized QHT grafts have a higher failure strength than 10-mm patellar tendon grafts. Therefore the strength of the graft cannot account for the higher clinical failure rates of smaller hamstring grafts in active patients in clinical studies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Arthroscopy: The Journal of Arthroscopic & Related Surgery - Volume 31, Issue 6, June 2015, Pages 1091–1096
نویسندگان
, , , ,