کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4043209 1603494 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Femoral Tunnel Apertures on the Lateral Cortex in Anterior Cruciate Ligament Reconstruction: An Analysis of Cortical Button Fixation
ترجمه فارسی عنوان
تونل فمورال دیافراگم در قشر جانبی در بازسازی سفتی قدامی قدامی: تجزیه و تحلیل رفع اشکال قورباغه
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

PurposeIf the aperture of the oval-shaped femoral tunnel on the lateral cortex becomes bigger than half the size of the cortical button, the risk of fixation failure increases. This study investigated the effect of the location of the entry point and diameter of the femoral tunnel on the length of the major axis of the tunnel aperture in anterior cruciate ligament (ACL) reconstruction using an outside-in technique.MethodsSimulation of femoral tunnel drilling was performed on computed tomography (CT)-based 3-dimensional (3D) bone models obtained from 40 participants. The tunnel connected the center of the ACL footprint and various points on the lateral femoral surface. The diameter of the tunnel was set at 4.2 mm, 5.2 mm, or 6 mm, depending on the commercially available outside-in surgical systems (Arthrex, Naples, FL and Smith & Nephew, Andover, MA). The length of the major axis of the oval-shaped aperture on the lateral femoral surface was measured.ResultsWhen the tunnel was introduced at 2 cm from the lateral epicondyle in a 45° anteroproximal direction, the major axis was lengthened to 130.7% ± 9.0% (P < .001) of the tunnel diameter, and it was more than 6.5 mm in 65% of participants in whom a 5.2-mm-diameter tunnel was drilled. When the entry point was 3 cm from the lateral epicondyle, 60% of participants had an oval-shaped aperture with a major axis of more than 6.5 mm, even though the diameter of the tunnel was only 4.2 mm.ConclusionsThe risk of fixation failure of a cortical button increases if the entry point for drilling is 2 cm or further from the lateral epicondyle and the tunnel diameter is more than 5 mm.Clinical RelevanceThis study indicates the potential risk of cortical button fixation failure caused by an oval tunnel aperture on the lateral femoral surface in ACL reconstruction using the outside-in technique.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Arthroscopy: The Journal of Arthroscopic & Related Surgery - Volume 30, Issue 7, July 2014, Pages 841–848
نویسندگان
, , , , , , , ,