کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4043725 1603504 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effects of Tunnel Dilation and Interference Screw Position on the Biomechanical Properties of Tendon Graft Fixation for Anterior Cruciate Ligament Reconstruction
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Effects of Tunnel Dilation and Interference Screw Position on the Biomechanical Properties of Tendon Graft Fixation for Anterior Cruciate Ligament Reconstruction
چکیده انگلیسی

PurposeThe purpose of this study was to evaluate the effects of screw position and compaction of the bone tunnel on the strength of the flexor tendon graft after fixation using interference screws.MethodsForty fresh-frozen porcine tibias were used for this study. The digital flexor tendons were folded into a quadrupled graft measuring 9 mm in diameter. In the extraction-drilling group, tibial bone tunnels were drilled with a conventional cannulated 9-mm drill bit in a single step. In the compaction-drilling group, bone tunnels were drilled using a cannulated 7-mm drill bit and were expanded to a final diameter of 9 mm in 0.5-mm increments by placement of dilators with increasing diameter. The grafts were fixed using 9 × 30-mm titanium screws in central and eccentric positions. Specimens underwent a cyclic-loading test, and the surviving specimens were then loaded until failure.ResultsGraft displacement after 1,500 loading cycles occurred significantly more often in the extraction-drilling group with eccentric screw placement than in the groups of extraction-drilling (P < .05) and compaction-drilling (P < .01) with central screw placement. There were no statistically significant differences for the maximum screw insertion torque, maximum load at failure, or stiffness among the 4 groups. One strand of the quadrupled tendon grafts showed partial injury during screw insertion in 3 (30%) and 4 (40%) of 10 specimens of the extraction-drilling and compaction-drilling groups with central screw placement, respectively.ConclusionsCentral screw placement significantly decreased the displacement of the tendon graft in comparison with eccentric screw placement in the extraction-drilling condition. Compaction of the bone tunnel walls by serial dilation in a central screw position did not increase the strength of interference screw fixation of a soft tissue graft.Clinical RelevanceWhen using the extraction method and fixing the graft in an eccentric position, it is advisable to provide additional fixation outside the tunnel to prevent slippage of the graft.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Arthroscopy: The Journal of Arthroscopic & Related Surgery - Volume 29, Issue 11, November 2013, Pages 1804–1810
نویسندگان
, , , , ,