کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4043814 1603513 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Biomechanical Comparison of Open and Arthroscopic Latarjet Procedures
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Biomechanical Comparison of Open and Arthroscopic Latarjet Procedures
چکیده انگلیسی

PurposeTo biomechanically compare the effectiveness of the standard open and arthroscopic techniques of the Latarjet procedure to address a critical anterior glenoid defect in combination with a capsular insufficiency.MethodsTranslation testing of 12 human cadaveric shoulder specimens was performed in a robot-assisted setup under 3 different conditions: (1) intact/vented shoulder joint, (2) combined anterior glenoid bone and capsular defect, and (3) open and arthroscopic Latarjet procedures. Testing was performed for each condition in 2 test positions: 60° of glenohumeral abduction with neutral rotation (ABD position) and 60° of abduction and external rotation (ABER position). Each position was tested with a passive humerus load of 30 N in the anterior, inferior, and anteroinferior directions. Translational movement of the humeral head was evaluated with and without the application of a 10-N load to the conjoint tendon (CJT).ResultsIn the ABD position, translations after the open Latarjet procedure significantly differed from the arthroscopic technique in the anterior and anteroinferior directions when testing was performed with loading of the CJTs (CJT loading). Without CJT loading, the open Latarjet technique showed significantly lower translations in the anterior, inferior (P = .004), and anteroinferior (P = .001) testing directions in the ABD position. In the ABER position, the arthroscopic procedure showed no significant difference compared with the standard open procedure.ConclusionsWe found a superior stabilization effect of the open Latarjet technique in the ABD position. The difference is ascribed to the anterior capsular repair, which was performed within the open technique and omitted during the arthroscopic procedure.Clinical RelevanceThe reduction of translation in a pure abduction position of the arm is more effectively performed with a conventional open Latarjet technique that includes a capsular repair. In combined ABER position, there was no difference found between the open and arthroscopic Latarjet techniques.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Arthroscopy: The Journal of Arthroscopic & Related Surgery - Volume 29, Issue 4, April 2013, Pages 630–637
نویسندگان
, , , , , , ,