کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4046152 1603550 2010 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A Biomechanical Comparison of Fan-Folded, Single-Looped Fascia Lata With Other Graft Tissues as a Suitable Substitute for Anterior Cruciate Ligament Reconstruction
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
A Biomechanical Comparison of Fan-Folded, Single-Looped Fascia Lata With Other Graft Tissues as a Suitable Substitute for Anterior Cruciate Ligament Reconstruction
چکیده انگلیسی

PurposeThe purpose of this study was to evaluate the initial biomechanical properties of a fan-folded, single-loop construct of fan-folded fascia lata allograft in comparison to other graft tissues currently being used for anterior cruciate ligament (ACL) reconstruction.MethodsEighteen fascia lata specimens were harvested from 11 donors and fan folded through a proprietary process. Bone–patellar tendon–bone (BPTB), tibialis anterior, tibialis posterior, and peroneus longus tendons were harvested from 4 additional donors. All soft-tissue grafts were tested to failure in an MTS machine (MTS Systems, Eden Prairie, MN) in a single-looped fashion. BPTB grafts were similarly clamped in freeze grips. The ultimate load to failure and stiffness were calculated for each graft type tested.ResultsThe mean ultimate load to failure was 3,266 N and stiffness was 414 N/mm for the single-looped fascia lata grafts (n = 18). There was no significant difference for ultimate load to failure and stiffness between the fascia lata and tibialis anterior (3,012 N and 342 N/mm, respectively), tibialis posterior (3,666 N and 392 N/mm, respectively), and peroneus longus (3,050 N and 346 N/mm, respectively) tendons. The fascia lata grafts performed significantly better (P < .001) than BPTB (1,404 N and 224 N/mm, respectively).ConclusionsA single-loop construct of fan-folded fascia lata allograft has, on biomechanical testing, initial ultimate tensile strength (3,266 N) and stiffness values equivalent to or better than several other graft tissues currently used in ACL reconstruction, including BPTB (1,403 N), tibialis anterior (3,012 N), tibialis posterior (3,666 N), and peroneus longus (3,050 N).Clinical RelevanceIn the face of potential allograft tissue shortages and increasing constraints on health care expenditures, the use of fascia lata has the potential to be a readily available graft for ACL reconstruction that performs as well as other grafts and at a comparable or lower cost.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Arthroscopy: The Journal of Arthroscopic & Related Surgery - Volume 26, Issue 12, December 2010, Pages 1641–1647
نویسندگان
, , , , , ,