کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4050303 1264920 2014 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Augmented screws in angular stable plating of the proximal humerus: What to do when revision is needed?
ترجمه فارسی عنوان
پیچ های افزایشی در انقباض زاویه ای پایینی از شکم پروگزیمال: چه کاری باید انجام شود وقتی که تجدید نظر مورد نیاز است؟
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی


• Removal of PMMA augmented angular stable screws in the proximal humerus
• No significant difference between augmented screws and the control
• Screw removal of augmented screws leads to no damage of the trabecular bone.
• Removal of augmented screws is easily feasible.

BackgroundBone cement augmentation of modified cannulated locking screws shows biomechanically and clinically good results for osteoporotic fracture management. Nevertheless, complications need to be considered. Therefore implant removal should be tested for feasibility.MethodsImplant removal was simulated in 7 pairs of osteoporotic cadaveric humeri: During screw removal from an angular stable proximal humerus plate, we measured the maximum torque of 14 augmented screws and the corresponding 14 non-augmented screws on the contralateral humeri. After screw removal, specimens were cut along the screw axes to macroscopically investigate the impact of screw removal on the surrounding bone. In addition, we established a technique for cement removal in cases in which the screw head is obstructed with cement and therefore disables the insertion of the screwdriver.FindingsThe screw extraction torque measurements showed no significant differences between the two groups regarding one screw (screw 4 augmented: 1.52 Nm, SD 0.25 Nm vs. screw 4 non-augmented: 1.80 Nm, SD 0.40 Nm; P = 0.20), whereas torque values for the second screw in the augmented group were lower than in the control group (screw 5 augmented: 0.72 Nm, 0.31 Nm vs. screw 5 non-augmented: 1.42 Nm, 0.52 Nm; P = 0.009). Macroscopy of the bone showed no damage to the trabeculae within the humeral head due to the removal.InterpretationThe removal of cannulated, polymethylmethacrylate-augmented, 2.8 mm titanium screws from an angular stable plate was uncomplicated, without the need for special instruments or increased torque for screw removal. No additional damage was visible at the bone-cement interface.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Biomechanics - Volume 29, Issue 9, November 2014, Pages 1023–1026
نویسندگان
, , ,