کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4050326 1264921 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Differences in knee flexion between the Genium and C-Leg microprocessor knees while walking on level ground and ramps
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Differences in knee flexion between the Genium and C-Leg microprocessor knees while walking on level ground and ramps
چکیده انگلیسی


• Randomized experimental crossover of the Genium and C-Leg prosthetic knees.
• 3D maker based motion capture with 8 camera Vicon system.
• Subjects walked on level ground, with ankle weights, 5 degree and 10 degree ramps.
• Genium increased knee flexion during stance and swing phase relative to C-Leg.
• Genium and C-Leg show significant impairment relative to non-amputee controls.

BackgroundMicroprocessor knees have improved the gait and functional abilities of persons with transfemoral amputation. The Genium prosthetic knee offers an advanced sensor and control system designed to decrease impairment by: allowing greater stance phase flexion, easing transitions between gait phases, and compensating for changes in terrain. The aim of this study was to determine differences between the knee flexion angle of persons using the Genium knee, the C-Leg knee, and non-amputee controls; and to evaluate the impact the prostheses on gait and level of impairment of the user.MethodsThis study used a randomized experimental crossover of persons with transfemoral amputation using the Genium and C-Leg microprocessor knees (n = 25), with an observational sample of non-amputee controls (n = 5). Gait analysis by 3D motion tracking of subjects ambulating at different speeds on level ground and on 5° and 10° ramps was completed.FindingsUse of the Genium resulted in a significant increase in peak knee flexion for swing (5°, p < 0.01, d = 0.34) and stance (2°, p < 0.01, d = 0.19) phases relative to C-Leg use. There was a high degree of variability between subjects, and significant differences still remain between the Genium group and the control group's knee flexion angles for most speeds and slopes.InterpretationThe Genium knee generally increases flexion in swing and stance, potentially decreasing the level of impairment for persons with transfemoral amputation. This study demonstrates functional differences between the C-Leg and Genium knees to help prosthetists determine if the Genium will provide functional benefits to individual patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Biomechanics - Volume 30, Issue 2, February 2015, Pages 175–181
نویسندگان
, , , , , ,