کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4054778 1265537 2012 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Functional outcome of ankle fracture patients treated with biodegradable implants
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Functional outcome of ankle fracture patients treated with biodegradable implants
چکیده انگلیسی

BackgroundBiodegradable devices have been developed to overcome the disadvantages of metallic implants especially the need for their subsequent removal, though they have their own drawbacks like poor mechanical properties and tissue reactions. Aim of this prospective study was to access the outcome of bimalleolar fractures fixed with biodegradable plates and screws.MethodsA prospective study was conducted between July 2006 and November 2008 comprising of sixteen patients with unilateral bimalleolar fractures. Fibula fractures were fixed with biodegradable plates and medial malleoli with screws. Patients were followed at two weeks, six weeks, three months, six months, twelve months and eighteen months. Final evaluation was done using Olerud Molander ankle score.ResultsSix patients had excellent results; four patients had good results and six patients had fair performance. No patient in this series had a poor outcome. One patient had both pain and swelling at 14 weeks postoperatively which settled down with debridement and antibiotics. None of the patients needed implant removal.ConclusionBiodegradable plates and screws when used to fix bimalleolar fracture along with restricted weight bearing, provide satisfactory fracture healing, good functional results and reduce the need of implant removal.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Foot and Ankle Surgery - Volume 18, Issue 3, September 2012, Pages 153–156
نویسندگان
, , , , ,