کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4060544 | 1603998 | 2014 | 4 صفحه PDF | دانلود رایگان |
This study sought to determine if there was an increased risk for surgical site contamination during stockinette application for a lower extremity surgery draping technique. Utilizing a simulated, sterile surgical field, stockinettes were applied over 10 cadaver lower extremities that were contaminated with non-pathogenic Escherichia coli on the foot. Of those, five specimens were then disinfected with Chloroprep and another 5 did not undergo any disinfection. All the specimens in which the stockinette was applied over a non-prepped foot showed proximal contamination. No contamination occurred in any of the specimens where the foot was disinfected. Stockinette can be a source of surgical site contamination when placed over a non-prepared foot.
Journal: The Journal of Arthroplasty - Volume 29, Issue 9, September 2014, Pages 1819–1822