Comparison between time-constrained and time-unconstrained optimization for power losses minimization in Smart Grids using genetic algorithms
ترجمه فارسی عنوان
مقایسه بهینه سازی زمان محدود و بدون محدودیت برای به حداقل رساندن تلفات قدرت در شبکه های هوشمند با استفاده از الگوریتم ژنتیک
کلمات کلیدی
شبکه های هوشمند، کاهش تلفات برق، تنظیم مجدد فیدر توزیع، بهینه سازی زمان محدود، نظریه گراف، الگوریتم های ژنتیک
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر هوش مصنوعی
چکیده انگلیسی

The power losses reduction is one of the main targets for any electrical energy distribution company. This paper studies the applicability of a control system based on a Genetic Algorithm (GA) on a portion of the actual Italian electric distribution network located in Rome and surroundings, managed by the ACEA Distribuzione S.p.A. The joint optimization of both power factor correction (PFC) and distributed feeder reconfiguration (DFR) is faced. The PFC is performed tuning the phases of the distributed generators (DGs) and the output voltage of the Thyristor Voltage Regulator (TVR). The DFR is performed by opening and closing the available breakers according to a graph based algorithm that is able to find all the possible radial configurations of the network. The joint PFC and the DFR optimization problem are faced by solving a suitable optimization problem, defining the fitness function that drives the GA. In order to have the opportunity to study a realistic future scenario, the actual network has been modified by introducing a few extra distributed generators. Aiming to validate the applicability of the proposed algorithm to an operative scenario, two different tests have been performed. The first one, referred to as time-unconstrained optimization, represents an ideal scenario where there are no constraints on time available for optimization. The second one, referred to as time-constrained optimization, represents a real scenario where the optimization must be completed within a time slot of one hour. Both tests have been performed by feeding the developed simulation tool with real data concerning dissipated and generated active and reactive power values. The comparison between results obtained in the two tests campaigns furnishes the opportunity to evaluate the effectiveness of the proposed control algorithm in real time, relying on the computational performances of an entry-level workstation. The obtained results encourage the use of derivative free methods in a real-time control scenario, showing that the performances achieved by the time-constrained optimization procedures are very close in terms of objective function values to the ones obtained by the time-unconstrained procedure.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Neurocomputing - Volume 170, 25 December 2015, Pages 353–367
نویسندگان
, , , ,