کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4061011 | 1604026 | 2012 | 6 صفحه PDF | دانلود رایگان |

The aim of the study was to analyze the incidence of squeaking with ceramic-on-ceramic total hip arthroplasty (THA) after 10 years of follow-up and the potential complications that could occur related to this phenomenon. One hundred THAs implanted between November 1999 and December 2000 were evaluated. Incidence of squeaking was investigated clinically with a questionnaire. Implant positioning was analyzed on x-rays and computer tomography. Of the 100 THAs, 5 patients presented with squeaking. All of them were active, sporty, and heavy men. Functional scores were comparable with nonsqueaking patients. There was no malpositioning on the x-ray analysis, no wear, and no loosening. We could not demonstrate any relation between squeaking and ceramic fracture. Squeaking noise appeared at a mean of 66 months postsurgery. It appears to be an isolated phenomenon without any consequences at 10-year follow-up.
Journal: The Journal of Arthroplasty - Volume 27, Issue 6, June 2012, Pages 1008–1013