کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4061021 1604026 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Wear Analysis of First-Generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty : An Average 9-Year Follow-Up
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Wear Analysis of First-Generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty : An Average 9-Year Follow-Up
چکیده انگلیسی

This is a retrospective review of 46 primary total hip arthroplasties using a first-generation highly cross-linked ultrahigh-molecular-weight polyethylene liner (Crossfire; Stryker, Mahwah, NJ) with an average of 9-year follow-up. The purpose of this study was to measure linear penetration rate of first-generation polyethylene to determine if it maintains its wear resistance and fatigue strength over an extended period compared with conventional polyethylene. The mean (SD) total penetration was 0.339 (0.204) mm, and the mean (SD) penetration rate was 0.037 (0.022) mm/y. Our study demonstrated a 74% reduction in total penetration of highly cross-linked polyethylene when compared with historical controls using conventional polyethylene at an average of 9 years. Our results support the belief that highly cross-linked polyethylene does retain its wear resistance over an extended period.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 27, Issue 6, June 2012, Pages 1064–1068
نویسندگان
, , , ,