کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4061407 1604013 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis of Tibial Component Rotation Following Total Knee Arthroplasty Using 3D High Definition Computed Tomography
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Analysis of Tibial Component Rotation Following Total Knee Arthroplasty Using 3D High Definition Computed Tomography
چکیده انگلیسی

Malrotation of the tibial component is associated with poor outcomes after total knee arthroplasty, yet the definition and evaluation of this problem remain controversial. Contributing factors to this controversy include inconsistent and cumbersome methods for measuring rotation, based upon transposed measurements from multiple computed tomography images. We developed and tested the reliability of a new, simple method for measuring tibial component rotation based upon a single, three-dimensional high definition, axial computed tomography image. Sixty individual knees after total knee arthroplasty were evaluated. The intra-reliability and inter-reliability both exceeded 0.9 whether the tibial component was made of titanium, cobalt–chrome or all-polyethylene. Based upon these findings we suggest that this technique be used for evaluating tibial component rotation in future studies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 28, Issue 8, Supplement, September 2013, Pages 106–111
نویسندگان
, , , , ,