کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4061632 1604049 2010 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Stability of Revision Acetabular Components Using the Rim-Fit Technique
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Stability of Revision Acetabular Components Using the Rim-Fit Technique
چکیده انگلیسی

Use of the rim-fit technique in revision acetabular surgery was reviewed for 20 hips in 18 patients. Defects at revision surgery included isolated medial segmental and global cavitary deficiencies with largely intact peripheral rim. A cementless acetabular component is placed to achieve a press-fit against the bony acetabular rim after morselized allograft and/or autograft was placed behind the cup. The average follow-up period was 68.3 months (5.7 years) (range, 27-112 months). Cup migration was assessed using digital radiography. Average vertical migration was 1.02 mm superiorly, and average horizontal migration was 0.8 mm medially. The abduction angle changed on average by 0.25°. Use of the rim-fit technique for treatment of cavitary acetabular defects is associated with component stability and minimal component migration.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 25, Issue 1, January 2010, Pages 128–132
نویسندگان
, , , , , ,