کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4061698 1604057 2009 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Minimum Ten-Year Results of a Porous Acetabular Component for Crowe I to III Hip Dysplasia Using an Elevated Hip Center
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Minimum Ten-Year Results of a Porous Acetabular Component for Crowe I to III Hip Dysplasia Using an Elevated Hip Center
چکیده انگلیسی

We conducted a retrospective study of the placement of porous-coated acetabular components using screws at more than 20 mm above the teardrop without structural bone graft for dysplastic hips to determine long-term outcome. Thirty hips (29 patients) were monitored for a mean of 15.2 years (range, 10.4-18.3 years) after surgery. Compared with 12 contralateral normal hips, the distance of the hip center from the teardrop was significantly high (26.8 ± 4.8 and 13.4 ± 2.7 mm P < .001); however, it was not laterally different (31. 5 ± 5.1 and 31.7 ± 5.0 mm). No acetabular components showed loosening. One metal shell was revised for wear and osteolysis. Morselized bone grafted in 25 hips was incorporated in all cases. Slight elevation of the hip center without lateralization in cementless cups fixed with screws was well tolerated for dysplastic hips.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 24, Issue 2, February 2009, Pages 187–194
نویسندگان
, , , , , ,