کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4061869 1604020 2013 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Successful Fixation of an Intertrochanteric Fracture After Hip Resurfacing Arthroplasty Using Cannulated Screws
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Successful Fixation of an Intertrochanteric Fracture After Hip Resurfacing Arthroplasty Using Cannulated Screws
چکیده انگلیسی
We report a case of successful treatment of a high, stable intertrochanteric fracture (type 1) in a 59-year-old man. He sustained the injury 8 years after the resurfacing procedure. The fracture was fixed using three 6.5-mm cannulated screws, and he has returned to his normal level of activities 8 months after the fixation. We have shown that fixation with cannulated screws may be an acceptable option for treatment of high trochanteric fractures where a stable anatomical reduction can be obtained. We have also included a review of the literature for other reported surgical treatment options of this complication.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 28, Issue 1, January 2013, Pages 197.e13-197.e16
نویسندگان
, , , ,