Femoral Component Neck Fracture After Failed Hip Resurfacing Arthroplasty
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Femoral Component Neck Fracture After Failed Hip Resurfacing Arthroplasty
چکیده انگلیسی
Failure on the femoral side after third-generation metal-on-metal hip resurfacing arthroplasty is suggested to be easily treated with conversion to conventional total hip arthroplasty. Clinical results of conversion for failed hip resurfacing arthroplasty with the use of primary femoral implants confirmed this for a short-term follow-up. We present a case of the occurrence of a stemmed femoral implant neck fracture in a patient who was earlier treated for a failed hip resurfacing. We advise to consider acetabular revision in case of (suspected) acetabular metal damage and to use a stem component with a relative large neck diameter.