کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4063071 1604041 2010 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Results of Isolated Femoral Component Revision With Well-Fixed Acetabular Implant Retention
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Results of Isolated Femoral Component Revision With Well-Fixed Acetabular Implant Retention
چکیده انگلیسی

The present study was undertaken to evaluate the clinical and radiological results of isolated femoral revisions conducted while retaining well-fixed cementless acetabular sockets. Thirty-nine patients that underwent isolated femoral stem revisions were reviewed. Mean age at time of surgery was 60.5 years, and mean follow-up duration was 4.2 years. Decisions to retain acetabular sockets were based on clinical and radiographic findings and intraoperative stabilities. During revisions, polyethylene liners were exchanged for metal-inlay polyethylene liners to have a metal-on-metal bearing surface in 23 cases. Mean Harris hip score improved from 58 points preoperatively to 85 points at final follow-up (P < .001). With the exception of one patient, no increases in acetabular radiolucent line numbers or thicknesses were observed during follow-up visits. Isolated femoral stem revisions with acetabular socket retention were found to provide excellent clinical and radiographic results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 25, Issue 8, December 2010, Pages 1188–1195
نویسندگان
, , , ,