کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4063103 1604088 2006 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The Influence of Femoral Component Design in the Elimination of Patellar Clunk in Posterior-Stabilized Total Knee Arthroplasty
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
The Influence of Femoral Component Design in the Elimination of Patellar Clunk in Posterior-Stabilized Total Knee Arthroplasty
چکیده انگلیسی

Patellar clunk occurs after posterior-stabilized total knee arthroplasty and is believed to be a design-related complication. This study was undertaken to define the incidence of patellar clunk with an optimized third-generation, posterior-stabilized prosthesis. One hundred ninety three patients with 238 knees were evaluated at a minimum of 2 years after primary total knee arthroplasty with a cemented, NexGen Legacy Posterior-Stabilized prosthesis (Zimmer, Warsaw, Ind). The mean follow-up was 48 months (range, 24-72 months). No patient manifested symptoms of patellar clunk or underwent surgery for any patello-femoral problem. These results support prior evidence that femoral component design is the primary cause of patellar clunk and that modifications incorporated into this third-generation, posterior-stabilized prosthesis has eliminated the problem.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 21, Issue 2, February 2006, Pages 167–171