کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4063103 | 1604088 | 2006 | 5 صفحه PDF | دانلود رایگان |

Patellar clunk occurs after posterior-stabilized total knee arthroplasty and is believed to be a design-related complication. This study was undertaken to define the incidence of patellar clunk with an optimized third-generation, posterior-stabilized prosthesis. One hundred ninety three patients with 238 knees were evaluated at a minimum of 2 years after primary total knee arthroplasty with a cemented, NexGen Legacy Posterior-Stabilized prosthesis (Zimmer, Warsaw, Ind). The mean follow-up was 48 months (range, 24-72 months). No patient manifested symptoms of patellar clunk or underwent surgery for any patello-femoral problem. These results support prior evidence that femoral component design is the primary cause of patellar clunk and that modifications incorporated into this third-generation, posterior-stabilized prosthesis has eliminated the problem.
Journal: The Journal of Arthroplasty - Volume 21, Issue 2, February 2006, Pages 167–171