کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4063319 1604039 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cementless Total Hip Arthroplasty With Alumina-on-Highly Cross-Linked Polyethylene Bearing in Young Patients With Femoral Head Osteonecrosis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Cementless Total Hip Arthroplasty With Alumina-on-Highly Cross-Linked Polyethylene Bearing in Young Patients With Femoral Head Osteonecrosis
چکیده انگلیسی

We asked whether total hip arthroplasties (THAs) using alumina-on-highly cross-linked polyethylene bearing would improve functional activity and reduce aseptic loosening, polyethylene wear, and osteolysis. Consecutive primary THAs were performed in 71 patients (73 hips) who were younger than 50 years (mean age, 45.5 years) with femoral head osteonecrosis. There were 48 men (50 hips) and 23 women (23 hips). Osteolysis was evaluated using radiographs and computed tomographic scanning. The average follow-up was 8.5 years (range, 7-9 years). The mean preoperative Harris hip score was 50.6 points, which improved to 96 points at the final follow-up. Preoperative functional activity was improved significantly at the latest follow-up. The mean polyethylene linear penetration was 0.05 ± 0.02 mm/y and no hip had aseptic loosening or osteolysis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 26, Issue 2, February 2011, Pages 218–223
نویسندگان
, , ,