کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4063409 1604058 2009 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Interobserver and Intraobserver Error in Distal Femur Transepicondylar Axis Measurement With Computed Tomography
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Interobserver and Intraobserver Error in Distal Femur Transepicondylar Axis Measurement With Computed Tomography
چکیده انگلیسی

On 2 separate occasions at least 1 week apart, 6 independent observers studied errors in identification of the transepicondylar axis (TEA) using computed tomography in 10 cadaveric knees. The reference surgical TEA was established by dissection of specimens. We found an average error of 2.6° (external rotation) when the TEA was identified by computed tomography. The error was significantly smaller when the TEA was identified by using a conventional axial image than when a 3-dimensional reconstruction image was used (P < .001, paired t test). No significant intraobserver error (P = .814, Wilcoxon rank test) was found when the measurement was performed using conventional 2-dimensional computed tomography images. However, significant interobserver difference was evident (P < .001, Friedman test).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 24, Issue 1, January 2009, Pages 96–100
نویسندگان
, , , , , ,