کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4063629 1604053 2009 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Revision of the Acetabulum With a Contemporary Cementless Component
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Revision of the Acetabulum With a Contemporary Cementless Component
چکیده انگلیسی

We evaluated the performance of a contemporary cementless acetabular component at a minimum of 5 years postoperatively. One hundred eighty-seven consecutive acetabular component revisions were performed using a hemispherical porous-coated component. Patients were followed prospectively with radiographs and Harris hip scores. Twenty patients died, leaving 158 patients (166 hips) available for follow-up at a mean of 91 months. No patients were lost. Eleven acetabular components (7%) required repeated revision, including 4 (2%) for aseptic loosening. Seven of the 145 unrevised acetabular components with radiographic follow-up (5%) were loose. The results of acetabular revision with this contemporary acetabular component were good but inferior to those of earlier-generation implants. This difference is likely multifactorial.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 24, Issue 6, Supplement, September 2009, Pages 58–63