کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4063998 1604081 2006 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Polished vs Rough Femoral Components in Grade A and Grade C-2 Cement Mantles
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Polished vs Rough Femoral Components in Grade A and Grade C-2 Cement Mantles
چکیده انگلیسی

The ideal surface for cemented femoral components remains controversial. Six polished stems were compared with 6 rough stems both with good cement mantle and also with poor cement mantles in a stair-climbing model. With good cement mantles, both the polished and the rough stems were loose by 6 million cycles. However, none were loose by radiographic criteria. With the poor cement mantle, both stems became loose earlier and developed more micromotion, the polished stems having significantly higher and earlier motion than the rough. Radiographic evidence of debonding was not visible until the stems had motion of more than 2000 μm. In the presence of a good cement mantle in this laboratory model there was no significant difference in the development of micromotion under fatigue stair-climbing conditions between a polished or grit-blasted femoral component. However, in the presence of a poor cement mantle, the polished components had earlier and higher micromotion. This study reinforces the importance of centralization and cement technique, particularly if using a polished surface finish.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 21, Issue 7, October 2006, Pages 1054–1063
نویسندگان
, , ,