Thermal Effects of Cement Mantle Thickness for Hip Resurfacing
چکیده انگلیسی

Hybrid hip resurfacing arthroplasty with uncemented acetabular and cemented femoral fixation is increasingly becoming popular as an alternative to total hip arthroplasty. There is concern about femoral neck fractures, and long-term survival has not yet been demonstrated. Thermal necrosis may be an important factor for neck fracture and will affect the viability of the femoral bone. This cadaveric study investigated the thermal effect of thick (1.5 mm, n = 3) and thin (0.5 mm, n = 3) cement mantles; 5 thermocouples were used to record temperature at the femoral bone/cement interface during hip resurfacing arthroplasty. The highest recorded temperatures were significantly higher when a thick cement mantle is used (45.4°C), compared to a thin cement mantle (32.7°C). To reduce the potential for thermal necrosis, the thin cement mantle technique is recommended.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 23, Issue 3, April 2008, Pages 454–458