کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4064230 1604072 2007 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Capsular-Enhanced Repair of the Short External Rotators After Total Hip Arthroplasty
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Capsular-Enhanced Repair of the Short External Rotators After Total Hip Arthroplasty
چکیده انگلیسی

Higher dislocation rates have been reported with the posterior approach to the hip. Empirical studies suggest that careful repair of the posterior structures significantly reduces this risk. However, studies examining the integrity of repair using plain radiographs and metallic markers have reported high failure rates. To explain this discrepancy, we performed a study using radiostereometric analysis to assess the repair. Ten patients were recruited. Markers were placed into the capsule and bone. The capsule and conjoined short external rotators were repaired through drill holes in bone. At 3 months, stress radiostereometric analysis radiographs were taken in internal and external rotation. Eight of 10 patients had a mean of 3.51-mm difference in separation, suggesting that the repair was intact. We recommend careful repair of posterior structures when using the posterior approach to reduce the risk of dislocation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 22, Issue 6, September 2007, Pages 840–843
نویسندگان
, , , , ,