کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4064233 1604072 2007 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Two-Stage Revision of Infected Uncemented Lower Extremity Tumor Endoprostheses
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Two-Stage Revision of Infected Uncemented Lower Extremity Tumor Endoprostheses
چکیده انگلیسی

We reviewed our experience with 2-stage revision of uncemented Kotz Modular Femoral and Tibial Replacement System prostheses from 1989 to 2004. A total of 180 lower extremity tumor prostheses were inserted, 15 of which underwent removal of the prosthesis for infection. Eleven patients underwent subsequent second-stage revision, and 4 underwent amputation. Of the 11 patients who underwent revision, 8 continue to be free of infection an average of 33 months postoperatively. Of these 8 patients, 6 were revised without removal of the diaphyseal anchorage piece, which were all well ingrown. Most successful revisions were in the group that developed infection within 6 months of their original procedure. Two-stage revision of uncemented tumor endoprostheses with retention of a well-ingrown stem can be associated with successful eradication of infection.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 22, Issue 6, September 2007, Pages 859–865