کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4064272 1604085 2006 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Eight-Year Results of Hydroxyapatite-Coated Hip Arthroplasty
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Eight-Year Results of Hydroxyapatite-Coated Hip Arthroplasty
چکیده انگلیسی

Ninety hips in 82 patients using Omnifit hydroxyapatite (HA)–coated prosthesis were followed for at least 7 years. All stems were stable at the final follow-up. However, aseptic loosening was found in 8 cups and 6 of them were revised. Two polyethylene wear were treated with inserts exchanged. The mechanical failure rate was 11.4% and the combined failure rate was 14.3% for HA-coated cup. Four other cups with wear and osteolysis without loosening or pain and 2 cups with polyethylene wear without osteolysis were still under observation. Our findings suggest that hip arthroplasties with HA coating on the smooth surface of a titanium cup is not reliable. The mid-term result of HA-coated stem is as good as that of porous-coated stem.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 21, Issue 4, June 2006, Pages 541–546
نویسندگان
, , , ,