کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4064307 1604087 2006 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The Influence of Ambient Theater Temperature on Cement Setting Time
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
The Influence of Ambient Theater Temperature on Cement Setting Time
چکیده انگلیسی

We have prospectively recorded ambient operating theater temperature from 186 total knee arthroplasties and the time taken for the cement to set at implantation. The majority of cases used Antibiotic Simplex cement (n = 131), and the rest, Simplex with tobramycin (n = 55). Set time was defined as when a no. 15 scalpel could not indent the cement surface at either the femoral or tibial interface. There was a reasonable negative correlation between temperature and setting time (Antibiotic Simplex: Pearson correlation coefficient, R = −0.674; Simplex with tobramycin: R = −0.655). There was also a considerable variation of setting time at any given theater temperature. There is an inverse relationship between ambient theater temperature and the setting time for Simplex cement, and surgeons should be aware that the setting time can vary considerably. Their operative protocol should take this into account.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 21, Issue 3, April 2006, Pages 381–384