کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4067530 1604392 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Scapholunate Ligament Reconstruction Using an Acellular Dermal Matrix: A Mechanical Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Scapholunate Ligament Reconstruction Using an Acellular Dermal Matrix: A Mechanical Study
چکیده انگلیسی

PurposeNumerous surgical techniques have been described for the treatment of chronic scapholunate ligament instability. We hypothesized that scapholunate ligament reconstruction using an acellular dermal matrix was biomechanically comparable to previously described surgical reconstructions.MethodsThe scaphoid and lunate with the entire scapholunate ligament were harvested from 15 cadaveric specimens. The scapholunate ligament was transected and reconstructed using an acellular dermal matrix (Arthroflex; LifeNet Health, Virginia Beach, VA) and 4 micro suture anchors in 10 specimens. Five specimens were kept with the native scapholunate ligament intact. Five other specimens were reconstructed using a 1.0-mm-thick dermal matrix, and a second cohort of 5 specimens was reconstructed using a 1.5-mm-thick matrix. Tensile testing of all specimens was performed using a servohydraulic material testing system and data acquisition software. The tensile test apparatus applied a distractive load of 10 mm/min (0.17 mm/s) until the specimens reached ultimate failure. Failure force, failure displacement, stiffness, and energy to failure were calculated.ResultsAll 5 specimens in the intact group failed at the scapholunate ligament midsubstance. The mean ultimate failure force was 172 N, with mean stiffness of 74 N/mm. In the reconstruction group with 1.0-mm dermal matrices, the mode of failure was at the suture–matrix interface in all specimens, whereas the 1.5-mm dermal matrix reconstruction cohort all failed at the bone–suture anchor interface. In the 1.0-mm reconstruction group, the mean ultimate failure force was 77 N, with mean stiffness of 24 N/mm. In the 1.5-mm dermal matrix reconstruction cohort, the mean ultimate failure force was 111 N, with mean stiffness of 30 N/mm.ConclusionsScapholunate ligament reconstruction using acellular dermal matrix and suture anchors demonstrated similar biomechanical properties to previously described reconstruction techniques.Clinical relevanceScapholunate ligament reconstruction using acellular dermal matrix warrants clinical investigation as a potential treatment alternative for chronic scapholunate instability.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Hand Surgery - Volume 37, Issue 8, August 2012, Pages 1538–1542
نویسندگان
, , , ,