کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4068095 1604383 2013 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
3-Dimensional Prebent Plate Fixation in Corrective Osteotomy of Malunited Upper Extremity Fractures Using a Real-Sized Plastic Bone Model Prepared by Preoperative Computer Simulation
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
3-Dimensional Prebent Plate Fixation in Corrective Osteotomy of Malunited Upper Extremity Fractures Using a Real-Sized Plastic Bone Model Prepared by Preoperative Computer Simulation
چکیده انگلیسی

PurposeTo assess the clinical outcome and accuracy of prebent plate fixation in corrective osteotomy for malunited upper extremity fractures using a plastic bone model manufactured by preoperative computer simulation.MethodsNine consecutive patients underwent computed tomography (CT)-based 3-dimensional corrective osteotomy for malunited upper extremity fractures. There were 4 cubitus varus deformities, 1 cubitus valgus deformity, and 4 forearm diaphyseal malunions. We constructed a computer model of the affected bones using the CT data and simulated the 3-dimensional deformity correction on a computer. A real-sized plastic model of the corrected bone was manufactured by rapid prototyping. We used a metal plate, prebent to fit the plastic bone model, in the actual surgery. Patients were evaluated after an average follow-up of 22 months (range, 14–36 mo). We retrospectively collected radiographic and clinical data at the most recent follow-up and compared them with preoperative data. We also performed CT after surgery and evaluated the error in corrective osteotomy as the difference between preoperative simulation and postoperative bone model.ResultsThe range of forearm rotation and grip strength in patients with forearm malunions improved after corrective osteotomies of the radius and ulna. Wrist pain, which 2 patients with forearm malunion had experienced before surgery, disappeared or decreased substantially after surgery. Radiographic examination indicated that preoperative angular deformities were nearly nonexistent after all corrective osteotomies. Three-dimensional errors in the corrective osteotomy using a prebent plate, as evaluated by CT data, were less than 3 mm and 2°.ConclusionsPrebent plate fixation in corrective osteotomy for malunited upper extremity fractures using a 3-dimensionally corrected, real-sized plastic bone model prepared by preoperative computer simulation is a precise and relatively easily performed technique that results in satisfactory clinical outcome.Type of study/level of evidenceTherapeutic IV.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Hand Surgery - Volume 38, Issue 5, May 2013, Pages 909–919
نویسندگان
, , , , , ,