کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4069277 | 1604403 | 2011 | 6 صفحه PDF | دانلود رایگان |

PurposeWe studied 2 methods used for screw placement through a volar approach for fixation of scaphoid fractures.MethodsWe performed measurements on 20 computed tomography scans of unfractured scaphoids. A central virtual guidewire was computed in 10 scaphoids with the wrist in neutral or in extension and ulnar deviation. Second, we compared the central guidewire and a guidewire representing a volar approach to the scaphoid avoiding the trapezium.ResultsThe central guidewire passed through the trapezium in all cases with the wrist either in neutral or in extension and ulnar deviation. There was a statistically significant difference only in the sagittal plane. When the central guidewire was compared with a guidewire placed through a standard volar approach, the latter was more eccentric in the distal and waist portions.ConclusionsWe showed that central placement throughout the scaphoid with a standard volar approach is not feasible without partially resecting, manipulating, or drilling through the trapezium.Clinical relevanceOur data suggest that a volar transtrapezial approach can be an alternative for optimum central placement in volar percutaneous fixation of scaphoid fractures.
Journal: The Journal of Hand Surgery - Volume 36, Issue 10, October 2011, Pages 1669–1674