کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4069767 1604439 2008 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of Ulnar-Shortening Osteotomy With a New Trimed Dynamic Compression System Versus the Synthes Dynamic Compression System: Clinical Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Comparison of Ulnar-Shortening Osteotomy With a New Trimed Dynamic Compression System Versus the Synthes Dynamic Compression System: Clinical Study
چکیده انگلیسی

PurposeUlnar-shortening osteotomy has become common in the treatment of symptomatic positive ulnar variance. Our goal was to evaluate prospectively a new dynamic compression plating system in comparison with a commonly used dynamic compression system. In contrast with other systems, the new system uses a slotted hole that enables fixation of the plate to the bone prior to performing the osteotomy, a fitted compression clamp, and a lag screw. Cutting guides that attach directly to plate eliminate the need for freehand osteotomies.MethodsThirty-seven patients were treated with a 3.5-mm, 6-hole dynamic compression plate with distraction device (Synthes, Paoli, PA) and compared with 17 patients treated with a new dynamic compression system manufactured by Trimed (Valencia, CA). Procedure length was recorded. The patients were evaluated for amount of shortening, pain, range of motion, grip strength, time to union, and return to work as well as with validated outcome measures.ResultsImprovement was found in all measures although no difference was found between the 2 groups other than significantly shorter length of operation with the Trimed system (a mean of 2 hours with the Synthes system vs 1 hour with the Trimed system). Ten plates were removed in the Synthes group and 4 plates were removed in the Trimed group because of symptomatic prominence of the plate. There were no infections, delayed unions, or nonunions in either group.ConclusionsThe new Trimed plating system for ulnar shortening was found to be as effective as the Synthes system and with a shorter procedure time. This may be related to the different measuring periods, although years of practice with the Synthes technique preceded this study. We believe the shortened procedure time for the Trimed system is due to its technical advantages.Type of study/level of evidenceTherapeutic III.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Hand Surgery - Volume 33, Issue 9, November 2008, Pages 1493–1497
نویسندگان
, , ,