کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4069977 1604388 2012 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Biomechanical Analysis of a Transverse Olecranon Fracture Model Using Tension Band Wiring
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Biomechanical Analysis of a Transverse Olecranon Fracture Model Using Tension Band Wiring
چکیده انگلیسی

PurposeTo determine (1) the most distal site at which a tension band construct can maintain bony alignment during dynamic loading of a transverse, length-stable olecranon osteotomy; (2) the location of displacement during cyclical loading; and (3) the ultimate load to failure of the fixation.MethodsWe divided 23 non-osteoporotic, fresh-frozen upper extremities into 4 groups. We created transverse osteotomies at 25% of the olecranon surface in group 1, 50% in group II, 75% in group III, and 100% in group IV. We used standard tension band wiring technique to stabilize each osteotomy. We mounted specimens on a biomechanical testing machine at 90° elbow flexion and subjected them to a 150-N sinusoidal load through the triceps tendon at 1 Hz for 500 cycles. An optical motion tracking system synchronized with the testing machine–measured displacement of the osteotomy in any plane. On completion of cycling, we loaded specimens at 1 mm/s until 2-mm displacement occurred. We analyzed data to determine the effect of the location of the osteotomy on load to failure and location of displacement.ResultsOf the 23 specimens, 21 survived the cycling process. The 2 specimens that failed were both in group II (50%). Excluding these 2 specimens, the average displacement at the 3 virtual points was less than 1.05 mm in all 4 osteotomy groups. There were no statistical differences between groups. Load to failure was 476, 361, 511, and 610 N for groups I to IV, respectively. Differences between groups were not statistically significant.ConclusionsThe stability achieved with tension band wire fixation did not vary with the location of the osteotomy.Clinical relevanceBased on this biomechanical study, when it is properly executed, tension band wire fixation may be used effectively for transverse, length-stable fractures of the olecranon regardless of the amount of articular surface included on the proximal fragment.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Hand Surgery - Volume 37, Issue 12, December 2012, Pages 2506–2511
نویسندگان
, , , , ,