کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4071695 1604524 2007 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Complications of circular plate fixation for four-corner arthrodesis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Complications of circular plate fixation for four-corner arthrodesis
چکیده انگلیسی

Four corner arthrodesis is an accepted salvage operation for scapholunate advanced collapse and scaphoid non-union advanced collapse. Circular plates were introduced in 1999 and promoted as a rapid and more stable method for this procedure. A retrospective chart review was performed on all patients who were treated with the Spider Limited Wrist Fusion Plate (Kinetikos Medical Inc., San Diego, CA). Sixteen patients were identified and followed clinically and with X-rays for an average of 16 (range 5–38) months. Nine out of the 16 patients (56%) had complications, including non-union (25%), delayed union (6%), dorsal impingement (25%), radial styloid impingement (6%) and broken screws (13%). The purpose of this study was to compare our complication rate using circular plates with published outcomes using traditional methods of fixation: this study identified a significantly higher complication rate and lower union rate using circular plate fixation for four-corner arthrodesis compared with previously published techniques.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Hand Surgery: British & European Volume - Volume 32, Issue 1, February 2007, Pages 50–53
نویسندگان
, , , , ,