کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4073396 1266980 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparing conventional and computer-assisted surgery baseplate and screw placement in reverse shoulder arthroplasty
ترجمه فارسی عنوان
مقایسه پایه جراحی معمولی و کامپیوتری و قرار دادن پیچ در شریان آرتروپلاستی معکوس
کلمات کلیدی
علوم پایه، تکنیک جراحی جراحی کامپیوتری، آرتروپلاستی شانه معکوس
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

BackgroundPreoperative planning and intraoperative navigation technologies have each been shown separately to be beneficial for optimizing screw and baseplate positioning in reverse shoulder arthroplasty (RSA) but to date have not been combined. This study describes development of a system for performing computer-assisted RSA glenoid baseplate and screw placement, including preoperative planning, intraoperative navigation, and postoperative evaluation, and compares this system with a conventional approach.Materials and methodsWe used a custom-designed system allowing computed tomography (CT)–based preoperative planning, intraoperative navigation, and postoperative evaluation. Five orthopedic surgeons defined common preoperative plans on 3-dimensional CT reconstructed cadaveric shoulders. Each surgeon performed 3 computer-assisted and 3 conventional simulated procedures. The 3-dimensional CT reconstructed postoperative units were digitally matched to the preoperative model for evaluation of entry points, end points, and angulations of screws and baseplate. Values were used to find accuracy and precision of the 2 groups with respect to the defined placement. Statistical analysis was performed by t tests (α = .05).ResultsComparison of the groups revealed no difference in accuracy or precision of screws or baseplate entry points (P > .05). Accuracy and precision were improved with use of navigation for end points and angulations of 3 screws (P < .05). Accuracy of the inferior screw showed a trend of improvement with navigation (P > .05). Navigated baseplate end point precision was improved (P < .05), with a trend toward improved accuracy (P > .05).ConclusionWe conclude that CT-based preoperative planning and intraoperative navigation allow improved accuracy and precision for screw placement and precision for baseplate positioning with respect to a predefined placement compared with conventional techniques in RSA.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Shoulder and Elbow Surgery - Volume 24, Issue 7, July 2015, Pages 1112–1119
نویسندگان
, , , , ,