کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4073508 1266983 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Glenoid subchondral bone density distribution in male total shoulder arthroplasty subjects with eccentric and concentric wear
ترجمه فارسی عنوان
توزیع تراکم استخوان غده تیروئید در مردان کلسترول شانه مردانه با سایش غلیظ و غلیظ
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

BackgroundGlenoid component loosening in total shoulder arthroplasty may be prevented by component placement on a congruent and adequate bony surface. Glenoid subchondral bone density (SBD) variability may be correlated with this concept. This study analyzed the 3-dimensional distribution of glenoid SBD in total shoulder arthroplasty patients with osteoarthritis.Materials and methodsThree-dimensional computed tomography osteoabsorptiometry (CT-OAM) was performed in 42 men (21 with eccentric and 21 with concentric wear patterns) with glenohumeral arthritis. Glenoid SBD was measured from the joint surface based on 5 clinically relevant topographic zones. The correlation of the wear pattern with the SBD distribution was investigated.ResultsThe glenoid subarticular layers could be separated into distinct regions: calcified cartilage (≤1.5 mm), subchondral plate (2-4.5 mm) and cancellous bone (≥5 mm). There were significant differences in SBD among these layers within and between patients with concentric and eccentric wear patterns. In concentric glenoids, the SBD distribution was homogeneous, with greater mineralization in the central zone, 1,749.1 ± 162.3 Hounsfield units (HU) (at 2.5 mm), compared with the posterior, anterior, and superior zones (P < .001). In the eccentric group, the SBD distribution was inhomogeneous. Mineralization was greatest in the posterior zone, 1,739.0 ± 172.6 HU (at 2.5 mm), followed by the inferior zone, 1,722.1 ± 186.6 HU (at 3 mm).ConclusionThis study represents the first study using CT-OAM to evaluate the 3-dimensional SBD distribution of the glenoid vault for different arthritic wear patterns. The study findings indicate that the SBD distribution is dependent on (1) depth from the articular surface, (2) topographic zone, and (3) wear pattern. CT-OAM may be an effective tool to assist in preoperative planning for shoulder arthroplasty.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Shoulder and Elbow Surgery - Volume 24, Issue 3, March 2015, Pages 416–424
نویسندگان
, , , , , , ,