کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4074122 1266999 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Clinical and radiographic results of cementless reverse total shoulder arthroplasty: a comparative study with 2 to 5 years of follow-up
ترجمه فارسی عنوان
نتایج کلینیکی و رادیوگرافی بدون آرتروپلاستی شانه ای با ساییدگی بدون سیم: یک مطالعه مقایسه ای با 2 تا 5 سال پس از پیگیری
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

BackgroundMost studies of reverse total shoulder arthroplasty (RTSA) involve cemented humeral stems. To our knowledge, this is the first study to compare the results of cementless RTSA, using a porous-coated stem designed for uncemented fixation, with cemented RTSA.MethodsA prospective database of patients undergoing RTSA was retrospectively reviewed for patients with a diagnosis of cuff tear arthropathy or severe rotator cuff deficiency with minimum 2-year follow-up. Of these, 37 patients had cemented RTSA and 64 patients had cementless RTSA. Outcome measures included Constant-Murley scores, American Shoulder and Elbow Surgeons scores, visual analog pain scale scores, range of motion, patient satisfaction, and radiographic evidence of complication.ResultsCompared with preoperative values, both cohorts demonstrated significant improvements (P < .01) in all functional scores, active forward elevation, and active internal rotation. There was no significant difference (P > .05) in comparing the changes in these values after surgery between the cemented and cementless cohorts. On radiographic evaluation, there was no evidence of loosening or humeral components “at risk” of loosening in either group. There was no significant difference (P = 1.0) in the incidence of humeral component radiolucent lines between the cemented and uncemented cohorts. There was no significant difference (P = .30) in the incidence of scapular notching between the cemented (n = 8) and uncemented (n = 10) cohorts.ConclusionCementless fixation of a porous-coated RTSA humeral stem provides clinical and radiographic outcomes equivalent to those of cemented stems at minimum 2-year follow-up. With advantages such as simplified operative technique, no cement-related complications, greater ease of revision, and long-lasting biologic fixation, uncemented fixation may provide several benefits over cemented fixation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Shoulder and Elbow Surgery - Volume 23, Issue 8, August 2014, Pages 1208–1214
نویسندگان
, , , , , ,