کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4074532 1267013 2011 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Instability after reverse total shoulder replacement
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Instability after reverse total shoulder replacement
چکیده انگلیسی

BackgroundDespite advances in technique and implant design, instability after reverse total shoulder arthroplasty remains a challenging postoperative complication.Materials and methodsWe examined our institutions’ first 57 reverse total shoulder arthroplasties performed during a 3-year period (2004-2006). There were 9 cases of instability, all occurring within the first 6 months after surgery.ResultsAll 9 patients had compromise of the subscapularis tendon at the time of initial reverse total shoulder implantation. With regard to implant positioning, 2 patients had superiorly inclined metaglenes and 3 had metaglenes positioned superior to the inferior glenoid. Each patient with a dislocation had at least 1 revision surgery, and 4 patients had underlying infection. At most recent follow-up, only 3 patients had a concentrically reduced reverse total shoulder arthroplasty in place whereas 3 remained explanted, 2 chronically dislocated, and 1 chronically subluxated.ConclusionsEarly instability after reverse total shoulder arthroplasty can be related to inadequate soft tissue, inadequate deltoid tension, malpositioned implants, and/or infection, and outcomes of treatment of early instability are generally poor.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Shoulder and Elbow Surgery - Volume 20, Issue 4, June 2011, Pages 584–590
نویسندگان
, , , , , , ,