کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4075560 1267042 2012 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Suprapectoral or subpectoral position for biceps tenodesis: biomechanical comparison of four different techniques in both positions
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Suprapectoral or subpectoral position for biceps tenodesis: biomechanical comparison of four different techniques in both positions
چکیده انگلیسی

HypothesisThe aim of this study was to compare different techniques for tenodesis of the long head of biceps tendon (LHB) in the suprapectoral and subpectoral position to test the hypothesis that using shorter screws at the subpectoral position would achieve a similar primary ultimate failure load (UFL) as the longer screws at the suprapectoral position, that both types of tenodesis screws achieve comparable UFL, and that knotless suture anchor techniques can be performed at the subpectoral position in cortical bone and reach a UFL similar to tenodesis screws.MethodsOn 42 fresh frozen human cadavers divided into 6 groups, 4 different techniques for LHB tenodesis were performed localized 10 mm and 50 mm, respectively, distal to the entrance of the bicipital groove. Two techniques with tenodesis screws (Bio-Tenodesis screw, Biceptor) and 2 with knotless suture anchors (Bio-SwiveLock, Footprint PK) were tested. Under a 10-N preload, an axial cyclic load with 100 cycles, 1-Hz frequency, and 50-N maximal load was applied. UFL was evaluated with an axial traction of 0.2 mm/s until decrease of tension. LHB dislocation was measured by 3-dimensional photogrammetry.ResultsAll techniques except the subpectoral Bio-SwiveLock had a dislocation <3 mm after cyclic loading. The highest mean UFL was measured for the suprapectoral Bio-Tenodesis screw (218.3 ± 59.7 N) and the lowest with the subpectoral Footprint PK (99.1 ± 16.4 N). The UFL of suture anchors were significantly lower than those of interference screws (P < .01). UFL was not significantly different for type of interference screw, the type of suture anchor, or tenodesis localization. Different failure mechanisms were evaluated for suture anchors and interference screws.ConclusionDue to the biomechanical testings interference screws are appropriate devices for suprapectoral and subpectoral biceps tenodesis resisting cyclic loading and attaining a satisfactory, whereas the knotless suture anchors sustained a significant about 50% lower UFL, and can only be recommended conditionally for LHB tenodesis regarding primary stability.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Shoulder and Elbow Surgery - Volume 21, Issue 1, January 2012, Pages 116–125
نویسندگان
, , , , , ,