کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4075721 1267047 2008 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Biomechanical evaluation of a pre-contoured clavicle plate
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Biomechanical evaluation of a pre-contoured clavicle plate
چکیده انگلیسی

Recent attention has been focused on the operative treatment of mid-shaft fractures of the clavicle. This study compares the in-vitro biomechanical properties of a pre-formed titanium clavicle plate (Acumed) to a Synthes 3.5 mm limited-contact dynamic-compression (LCDC) plate using a cadaveric osteotomy model. An osteotomy was performed on 7 pairs of human clavicles and were randomly plated with either a Synthes 3.5 mm LCDC stainless steel plate or an Acumed titanium pre-contoured clavicle plate. After plating, specimens were tested on an EnduraTEC material testing apparatus for axial compression and tension strength, as well as torsional strength in compression and tension. Biomechanical test results for plated specimens are reported for the LCDC plate and the Acumed plate, and the 2 plates are compared.This exploratory study supports investigations with larger sample sizes to determine if theAcumed pre-contoured plate differs from the LCDC plate in biomechanical properties and theclinical implications of such differences.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Shoulder and Elbow Surgery - Volume 17, Issue 5, September–October 2008, Pages 815–818
نویسندگان
, , , , ,