کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4077648 1267224 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Improvement of primary stability in ACL reconstruction by mesh augmentation of an established method of free tendon graft fixation. A biomechanical study on a porcine model
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Improvement of primary stability in ACL reconstruction by mesh augmentation of an established method of free tendon graft fixation. A biomechanical study on a porcine model
چکیده انگلیسی

PurposeThe aim of the present study was to compare primary stability in ACL reconstruction and ultimate load to failure of a mesh augmented hamstring tendon graft fixed with two cross pins to established hamstrings and bone-patellar-tendon-bone (BTB) graft fixation methods.MethodsForty fresh porcine femora were divided into four groups: (A): BTB graft fixed with two RigidFix® pins, (B): hamstring tendon graft fixed with a Milagro® interference screw, (C): hamstring tendon graft fixed with two RigidFix® pins, and (D): hamstring tendon graft augmented with Ultrapro® mesh fixed with two RigidFix® pins. Each graft underwent cyclic loading in tension and load to failure. Elastic and plastic displacements were measured by 3-dimensional digital image correlation. Groups were compared by one-way ANOVA and Tukey–Kramer post-hoc tests.ResultsAfter 1000 cycles, the mean plastic displacement was lowest in the BTB graft (p < 0.001). Plastic displacement was significantly lower in the mesh augmented group compared to the plain hamstring graft and the Milagro screw group (p < 0.05). Load to failure was highest in the mesh-augmented group; significant to the hamstring tendon (p = 0.023).ConclusionAlthough the BTB-graft represented the most stable construct against plastic displacement in our study, mesh augmentation of free tendon grafts significantly increased primary stability and reduced plastic displacement of femoral cross pin fixation. This new augmentation device may better protect the hamstrings graft from secondary elongation during postoperative rehabilitation.Clinical relevanceMesh augmentation seems to be an effective technique to stabilise free hamstring tendon autografts during postoperative rehabilitation with significant reduction of graft slippage.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Knee - Volume 20, Issue 2, March 2013, Pages 79–84
نویسندگان
, , , , ,