چکیده انگلیسی

Study DesignRetrospective case report.ObjectiveTo report the first known case of immunological camouflage of a metal spinal implant with carbon coating.Summary of Background DataMetal sensitivity is common and is a consideration when choosing orthopedic implants in susceptible individuals. The sensitivity often is to nickel, cobalt, or chromium, and titanium is used as a safe alternative. However, when the allergy is also to titanium, solutions may be much more difficult. This case describes an innovative solution to a complex metal allergy that includes titanium in a child requiring spinal instrumentation for early-onset scoliosis.MethodsAt age 6 years 7 months, the patient underwent an uncomplicated placement of bilateral posterior Vertical Expandable Prosthetic Titanium Ribs (VEPTRs; Synthes, Inc., West Chester, PA). At that time, there were no known metal allergies. At 3 weeks, the right side had become erythematous and had serosanguineous drainage. It briefly improved after each of 2 surgical debridements and a course of intravenous antibiotics, but within 6 weeks of the index procedure, the pain was still worsening. A titanium allergy was suspected and blood was sent for allergy testing. A test confirmed hypersensitivity to titanium, niobium, molybdenum, iron, and aluminum, among others. The remaining rod was removed. An in vivo trial for tolerance to high-grade stainless-steel implants was done. The implant was removed after 2 weeks because of systemic symptoms that occurred.ResultsA plasma-spray, carbon-coated VEPTR rod was designed. A rod sample was inserted into the patient's forearm for trial. After 3 months, there was no appreciable reaction. Carbon-coated VEPTRs were placed without complications. The patient has undergone multiple lengthening using the carbon-coated VEPTRs.ConclusionsIn the rare patient with multiple allergies, choosing orthopedic implants can be challenging. An innovative carbon coating was applied by plasma spray to the VEPTR system, with good results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spine Deformity - Volume 2, Issue 1, January 2014, Pages 76–80
نویسندگان
, , ,