کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4098573 1268618 2010 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Inter- and intraobserver variability in the postoperative evaluation of transpedicular stabilization: computed tomography versus magnetic resonance imaging
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Inter- and intraobserver variability in the postoperative evaluation of transpedicular stabilization: computed tomography versus magnetic resonance imaging
چکیده انگلیسی

Background contextComputed tomography (CT) represents the state of the art for the postoperative verification of the implant position after transpedicular stabilizations. Magnetic resonance imaging (MRI) has not challenged the CT, yet, because of susceptibility artifacts but would be favorable as a diagnostic tool for its excellent soft-tissue qualities.PurposeA study that analyzed if an artifact-reduced MRI could overcome this problem and provide sufficient data for the postoperative assessment was conducted.Study designThe study design was a radiologic comparison of CT and MRI techniques evaluating pedicle screw placement after spinal fusion.Patient sampleFifty consecutive patients were given an MRI and a CT after a transpedicular stabilization surgery. Thirty-eight patients suffered from degenerative spinal disorders; three surgeries had become necessary because of spondylodiscitis, eight patients suffered from metastatic vertebrae destruction, and one patient experienced a fracture.Outcome measuresAny contact of a malpositioned pedicle screw with the dura and/or radicular structures was identified as an implant-associated complication and was compared with postoperative clinical patient findings.MethodsIn total, 338 pedicular screws were analyzed in regard to their intrapedicular position. The double-blind evaluation of MRI and CT data was carried out by two radiologists and two spine surgeons. Accuracy of the CT analysis was calculated based on the interobserver agreement of 100%. Magnetic resonance imaging accuracy was calculated.ResultsThe interobserver accuracy of the CT data amounted to a median of 89.8% and in the MRI data of 86.7%. Intraobserver comparisons showed a significant difference between CT and magnetic resonance evaluations in one observer (κ=0.293). In all other observers, the results were concordant with kappa values from κ=0.328 to κ=0.702. There was a high degree of agreement regarding the diagnosis of malpositioned pedicle screw and corresponding clinical symptoms between both techniques.ConclusionsThe presented data show that artifact-reduced MRI is equivalent to CT imaging in the postoperative evaluation of titanium spinal rod-screw systems. We therefore conclude that MRI should be considered as an alternative tool for the golden standard CT for postoperative imaging controls for its advantages in soft-tissue analysis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Spine Journal - Volume 10, Issue 4, April 2010, Pages 285–290
نویسندگان
, , , , , ,