کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4117098 1270292 2016 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Digital evaluation of orbital development after self-inflating hydrogel expansion in Chinese children with congenital microphthalmia
ترجمه فارسی عنوان
ارزیابی دیجیتال توسعه مداری بعد از گسترش هیدروژل خودبخودی در کودکان چینی با میکروفتالمی مادرزادی
کلمات کلیدی
اندازه گیری مدار، توسعه مداری، میکروفتالمی مادرزادی، هیدروژل خود تورفتگی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری های گوش و جراحی پلاستیک صورت
چکیده انگلیسی

SummaryBackgroundAssessment of the growth of bony orbit in children with blind microphthalmia is essential to its management. In this study, variables were measured to evaluate the development of the bony microphthalmic orbits after treatment with self-inflating hydrogel expanders.MethodsThis is a retrospective study with an interventional case series. Thirteen pediatric patients with congenital unilateral blind microphthalmia who had undergone tissue expansion with hydrogel expanders and computed tomography (CT) scanning before and after operation were included in the study. The orbital volume, depth, width, and height and retardation of the orbital rims before and after treatment were measured and analyzed using the iPlan Cranial Software.ResultsThe mean age at the time of first implantation was 44 months (range, 3–113 months). Of the 13 patients, eleven received orbital expansion, while two received socket expansion. In the orbital expansion group, the mean microphthalmic/contralateral ratio (MCR) of orbital volume was 79.3% before surgery, which increased to 89.8% 3 years post operation (P < 0.001). The mean MCR of orbital width also increased from 88.8% to 91.8% (P = 0.003). The development of inferior and lateral rims showed the greatest retardation before treatment; the retardation of these two rims decreased significantly at the final measurement (P = 0.004). It is also noted that the development of the microphthalmic orbits was limited in the two patients who only underwent socket expansion.ConclusionsThe affected orbit enlarged in children with congenital blind microphthalmia following treatment with hydrogel expanders; this suggested that microphthalmia-associated orbital asymmetry can be treated with self-inflating hydrogel expanders.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Plastic, Reconstructive & Aesthetic Surgery - Volume 69, Issue 5, May 2016, Pages 706–714
نویسندگان
, , , , ,