کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4118189 1270326 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Integra™ permits early durable coverage of improvised explosive device (IED) amputation stumps
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری های گوش و جراحی پلاستیک صورت
پیش نمایش صفحه اول مقاله
Integra™ permits early durable coverage of improvised explosive device (IED) amputation stumps
چکیده انگلیسی

SummaryIntroductionImprovised explosive device (IED) blasts cause serious injury. Survivors are left with multiple amputations, considerable soft tissue loss and open fractures with gross contamination. We present our early experience of Integra™ in the acute management of military wounds.MethodThe clinical records of all patients with IED injuries who underwent early reconstruction with Integra™ during the six month period between August and December 2009 in our unit were reviewed and data gathered prospectively.ResultsThere were 7 male soldiers, aged 21–31 years (mean = 26). All sustained trunk and limb injuries, including multiple amputations. Number of procedures prior to application of Integra™ was 4–10 (mean = 5). Application of Integra™ took place 6–24 days post-injury (mean = 13). Size of wounds covered with Integra™ was 1–11.5% TBSA (mean = 5%). Anatomical sites reconstructed included amputation stumps, and both upper and lower limbs.There was partial take of Integra in 3 wounds in 2 patients. All wounds were eventually treated with delayed split skin grafting and healed satisfactorily.ConclusionIEDs produce a large zone of injury with massive soft tissue damage, multiple discontinuous wounds which are significantly contaminated. The physiological insult is equivalent to a large cutaneous burn and there is a paucity of available donor sites. Multiple amputees also have a greater energy and power requirement1, 2, 3 and 4 and cannot spare remaining functional muscles as donors. The literature suggests that microvascular flaps have a high failure rate in military patients.5 Reconstruction began as soon as wounds were considered sufficiently clean.Integra™ was applied with the aim of providing higher quality coverage than that provided by split skin grafting alone (particularly for amputation stumps) whilst minimising operative time and morbidity.Integra™ allows timely closure of battlefield wounds with minimal operative time and morbidity. The procedure can begin whilst still in the acute phase and certainly before one would consider lengthy complex operations such as free flaps. Our experience suggests that Integra™ can allow early closure with robust tissue, promoting early rehabilitation and return to duties.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Plastic, Reconstructive & Aesthetic Surgery - Volume 66, Issue 12, December 2013, Pages 1717–1724
نویسندگان
, , ,