کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4120261 1270368 2009 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Correlation between vessel diameters of superficial and deep inferior epigastric systems: Doppler ultrasound assessment
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیماری های گوش و جراحی پلاستیک صورت
پیش نمایش صفحه اول مقاله
Correlation between vessel diameters of superficial and deep inferior epigastric systems: Doppler ultrasound assessment
چکیده انگلیسی

SummaryBackgroundThe deep inferior epigastric artery perforator (DIEAP) flap is a technically demanding procedure and the dissection is directly influenced by the size of the perforator vessels. There is a common belief that the size of the superficial inferior epigastric vein (SIEV) is inversely proportional to the perforators from the deep inferior epigastric system. To investigate the validity of this hypothesis, we evaluated and compared the diameters of the SIEV and deep inferior epigastric perforator vessels (DIEP-A and DIEP-V).MethodsBetween 2004 and 2006, 50 patients scheduled for breast reconstruction with autologous tissue were evaluated with colour Doppler ultrasound to determine the diameters of SIEV and DIE perforator vessels. The correlation between SIEV and ipsilateral DIEP-V, the correlation between DIE perforator vessels on each side and the impact of body mass index were assessed. Results were analysed statistically to compare the diameter of the SIEV with the largest perforator on the same side and the largest perforators on the contralateral side. Additionally, partial correlation coefficients were calculated to assess if there is an inverse correlation between SIEV and DIE perforators.ResultsDiameters of SIEV ranged from 0.50 to 4.06 mm. DIEP-A ranged from 1.00 to 3.49 mm, while DIEP-V ranged from 0.50 to 4.32 mm. There was a slightly inverse correlation between the size of SIEV and DIEP-V, but this was not statistically significant. However, the correlation between SIEVs on both sides was statistically significant. There was also a strong correlation between the size of DIEP-A and DIEP-V on the same side as well as the size of those on the contralateral side. However, the largest artery and vein matched only in 50% of perforator bundles on the right and 62% on the left side. In addition, the vessel diameters increased as the body mass index increased; however, this finding was significant only for perforator veins.ConclusionThe inverse correlation between the size of SIEV and DIEP-V was not significant. If SIEV and DIE perforator vessels are large on one side, they are also large on the other side. In addition, the larger the artery, the larger is the vein on the same perforator. However, the largest arteries and veins are not necessarily on the same perforator bundle.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Plastic, Reconstructive & Aesthetic Surgery - Volume 62, Issue 9, September 2009, Pages 1140–1147
نویسندگان
, , , , , ,