Cardiac Output Assessed by the Fourth-Generation Arterial Waveform Analysis System Is Unreliable in Liver Transplant Recipients
ترجمه فارسی عنوان
خروجی قلبی بررسی شده توسط سیستم تجزیه و تحلیل شکل موج شریانی چهارگانه در گیرندگان پیوند کبد غیر قابل اعتماد است
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
چکیده انگلیسی


• Managing fluctuated hemodynamics during liver transplantation is challenging.
• The fourth-generation FloTrac is not reliable during liver transplant surgery.
• The trending ability is not qualified during liver transplantation, either.

BackgroundLiver transplant recipients often have violent hemodynamic fluctuation during surgery that may be related to perioperative and postoperative morbidity. Because there are some considerations for the risk of the pulmonary arterial catheter (PAC), the conventional invasive device for cardiac output (CO) measurement, a reliable and minimally invasive alternative is required. We validated the reliability of CO measurements with the use of a minimally invasive FloTrac system with the latest fourth-generation algorithm in liver transplant recipients.MethodsForty liver transplant recipients without atrial fibrillation, valvular pathology, or intracardiac shunt were recruited in this prospective, observational study. CO values measured by use of PAC with continuous thermodilution method (COTh) and FloTrac devices (COFT) were collected simultaneously throughout the operation for reliability validation.ResultsFour hundred pairs of CO data points were collected in total. The linear regression analysis showed a high correlation coefficient (73%, P < .001). However, the percent error between COTh and COFT was 42.2%, which is worse than the established interchangeability criterion of 30%. The concordance rates were calculated at 89% and 59% by 4-quadrant plot and polar plot analysis, respectively. Neither met the preset validation criteria (>92% for the 4-quadrant plot and >90% for polar plot analyses).ConclusionsOur study demonstrates that the CO measurements in liver transplant recipients by the latest FloTrac system and the PAC do not meet the recognized interchangeability criterion. Although the result showed improvement in linear regression analysis, it failed to display a qualified trending ability.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Transplantation Proceedings - Volume 48, Issue 4, May 2016, Pages 1170–1175
نویسندگان
, , , , , , , , ,